![]() ![]() For that reason I used a regular 30a breaker in my main panel and have a spa panel with the gfci wired up between my panel and the control panel for the gfci capabilities. Personally I chose to use breakers and fuses protecting each circuit inside my control panel which help troubleshoot further is something else fails and also allows me to continue finishing my brewday if one of the circuits where to fail.Īlso 30a gfci breakers are not as common as the 50a type and usually cost more. This would still be safer from what I understand, than having a regular 120v lamp or appliance that draws say 5 amps plugged into a 15a-20a wall outlet right? what is protecting the cord in those scenerios if someone puts a 300w bulb in the lamp or the appliance malfunctions and draws more than the power cord is rated for? My point is if you design the control panel correctly the risk is still the same as any other outlet in your house as I see it. Īnother option would be to have breakers or fuses in your control panel and to not mess with the wall outlet (after adding the 50a gfci breaker) But rather have the circuits fused or protected from overdrawing in the panel. If the total load you want to put on that circuit is greater than 1,920-watts, you must install two separate circuits. Or you could use the 30 amp receptacle and 50 amp breaker, be careful and hope for the best. For example, a 15-amp circuit breaker has a safe load capacity of 1,440-watts, and a 20-amp circuit has a safe capacity of 1,920-watts. Conversely you could put a 50 amp cord end on your brewing equipment and use a 50 amp receptacle. As said above the correct thing to do here would be to put a thirty amp circuit breaker upstream from the 30 amp receptacle. Codes are an attempt to reduce the opportunity for unlikely things to happen. The person moving in might have an electric range and find it easier to get a plug that fits the receptacle you left in the wall and put it on the end of the range cord rather than replace the receptacle with a proper one. Codes are not written so much for situations where people know what they are doing but for what people might unknowingly do.įor example, you might leave this in this condition and move to a new house. This breaker is designed for MotorGuide motors that draw less than 50 amps. If you know the equipment you are using and will not be drawing more than 30 amps through the receptacle it will work but it will not be a code compliant installation. This circuit breaker protects the trolling motor from electrical damage. GeepKey Latest 50 Amp Generator Power Inlet Box, NEMA 3R Generator Receptacle 50 Amp, NEMA SS 2-50P PB50 Weatherproof Inlet Box, 125/250 Volt,12500 Watts Generator Transfer Switch, ETL Listed. If you did that it would over heat the receptacle. ![]() In this case it would be possible to draw more than the thirty amps the receptacle is rated for through it. Technically any wiring device, such as a receptacle, downstream from the circuit breaker should be rated the same or higher than the breaker. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |